Skip to main content
Lintel: Lintel / Lintel Beam

What is a lintel in construction?

A lintel, or lintel beam, is a short horizontal member over a door, window or other opening that carries the wall above it. In Indian buildings it is usually RCC, cast in place or precast, and it rests on the wall at both ends. A BOQ measures it as concrete, steel and shuttering.

Key facts

Material
Usually RCC; stone, steel and timber lintels exist
BOQ units
Concrete in m³, steel in kg, shuttering in m²
Where it appears
Door and window schedules, sections, brickwork measurement
Measurement rule
IS 1200 Part 3: a separate lintel is measured with the opening

How do you calculate lintel quantity?

Lintel length is the opening width plus the bearing at each end; multiply by the wall thickness and the lintel depth for concrete.

Worked example. A 1.00 m wide door in a 230 mm wall, with an illustrative 150 mm deep lintel bearing 200 mm on each side:

ItemWorkingQuantity
Lintel length1.00 + 2 × 0.201.40 m
RCC1.40 × 0.23 × 0.150.0483 m³
Shuttering, soffit over the opening1.00 × 0.230.23 m²
Shuttering, both sides2 × 1.40 × 0.150.42 m²

Take the bearing and section from the drawing; the figures here only show the method.

How is a lintel deducted from brickwork?

Under IS 1200 Part 3, a separate lintel is included in the size of the opening, so the opening deduction runs up to the top of the lintel. The lintel's end bearings are not deducted when their section is 0.1 m² or less.

For the door above, 2.10 m high: deduct 1.00 × (2.10 + 0.15) × 0.23 = 0.5175 m³ from the wall. The bearings are 0.23 × 0.15 = 0.0345 m² in section, below the 0.1 m² limit, so they stay in the brickwork. Openings of 0.1 m² or less are not deducted at all. Our IS 1200 guide covers the other deductions, and the brickwork rate guide prices the wall that results.

Lintel vs lintel band vs chajja

A lintel spans one opening; a lintel band runs continuously round the building at lintel level; a chajja is a projecting sunshade, often cast with the lintel.

When the drawings show a continuous band, measure it as one beam along its length and do not add separate lintels inside it. Measure a chajja as its own item, since its thickness, projection and steel differ from the lintel's. The structural drawing says which of these the building has.

Where do lintels appear in the drawings and the BOQ?

Opening sizes come from the door and window schedules; the lintel's depth, bearing and steel come from the sections or structural details. In the BOQ, lintels sit under RCC work and their openings under masonry deductions.

Make one row per lintel type: opening width, bearing, section and number of openings of that type. Counting lintels from the door and window schedule, rather than from the plan by eye, avoids missing the ventilator or kitchen openings. If a supplier quotes precast lintels, check the unit and section the rate assumes before comparing it with cast-in-place work.

Common mistakes with lintels

Most errors come from forgetting the bearing length, deducting the opening without the lintel depth, or counting a lintel inside a continuous band twice.

  • Clear span only. The lintel is longer than the opening by its two bearings.
  • Short deduction. Deduct the opening up to the top of the lintel, not just the frame height.
  • Missing steel. Lintel bars need their own BBS rows, with development length into the bearing where the drawing asks for it.
  • Revisions. A changed window schedule in a new GFC drawing changes every lintel over it.

Go deeper

Related terms

Sources

Checked 2026-11-03. Contract documents, tender conditions and the structural drawings for your project take precedence over the general rules on this page.

All construction terms in the glossary